General Specifications:
| Input voltage |
90VAC to 264VAC |
| Input frequency |
47Hz to 63Hz |
| Power factor |
>0.93 |
| Inrush current |
less than 30A at 115VAC
or 60A at 230VAC cold start, 25°C
|
| Efficiency |
85%~90% depends on models |
| Hold up time |
>20ms at rated load and 115VAC |
| Over load protection |
auto recovery |
| Short circuit protection |
auto recovery |
|
| Over voltage protection |
latch off |
| Operating temperature (open frame type) |
0°C to 70°C
derating: 2.5% / °C>50°C
|
| Cooling |
60% rated load free air convection
>60% rated load 20CFM forced air
|
| Storage temperature |
-20°C to +85°C |
| EMI |
EN55022 "B" |
| Harmonics |
EN61000-3-2 class D |
| EMS |
EN61000-4-2,-3,-4,-5,-6,-11 |
| Safety |
UL 60950-1, UL 60601-1
CSA C22.2 No. 60950-1 & 60601-1
TUV EN60950-1 & 60601-1
|
|